GIUNTO ISOLANTE ESTREMITA' A SALDARE PN 10
per gas e acqua
S = estremità a saldare
W = end to be welded
codice
dimensioni in mm
peso
code
dimensions in mm
weight
DN
S
A
E
C
B
L±2%
Kg
SS015
1/2"
3,25
21,3
46
90
28
210
0.5
SS020
3/4"
3,25
26,7
53
96
32
225
0.7
SS025
1"
3,38
33,4
60
105
35
245
1
SS032
1"1/4
3,56
42,2
71
117
36
270
1,5
SS040
1"1/2
3,68
48,3
77
121
37
280
1.7
SS050
2"
3,91
60,3
90
126
38
290
2,3
SS040
2"1/2
5,0
76,1
113
137
53
330
4,5
SS050
3"
5,49
88,9
127
172
56
400
6

INSULATING JOINT WELDING/WELDING PN10 for gas/water


Giunti Isolanti costruiti e collaudati secondo UNI- CIG 10284
Insulating Joints tested and manufactured in accordance to UNI-CIG 10284
CARATTERISTICHE MECCANICHE
MECHANICAL FEATURES

  ACCIAIO bicchiere : ASTM A 105
Hot forged socket : ASTM A 105
 

Tronchetti : API 5L Gr.B - UNI ISO 3183
Hot forged spigot : API 5L Gr.B
 

Anelli isolanti in policarbonato
Insulating rings in polycarbonate
 
Guarnizione in Hytrel 40 D Dupont
Gasket ring in Hytrel 40 D Dupont
 
Vernice epossifenolica
Epoxyphenolic painting
CARATTERISTICHE ELETTRICHE E IDRAULICHE
HYDRAULIC AND ELECTRICAL FEATURES

Pressione d'esercizio : 10 Kg/cm²
Working pressure: 10 Kg/cm²
Pressione di collaudo : 15 Kg/ cm²
Testing pressure : 15 Kg/ cm²
Tensione di isolamento in aria : 3 Kv
Dielectric resistance in dry air : 3 Kv

Resistenza di isolamento in aria : 5 Megaohm
Electrical insulation resistance in dry air : 5 Megaohm
Temperatura di esercizio : da -15° C a +70° C.
Working temperature : from -15° C up to +70° C..
 
 